CONTROLS
- Cad Cell Relay (Heating Only) (Note: A/C Ready Kit NOT Covered)
- Barometric Draft Regulator
- Circulator Control
- Emergency Switch (Not Wiring)
- Single-Acting Aquastat
- Thermostat (Manual Heat Only)
BURNER REPLACEMENT PARTS
- Burner Blast Tube (Std. Size)
- Burner Flange Gasket
- Cad Cell Assembly
- Delayed oil Valve Coil
- Electrode Assembly
- Nozzle Adapter
- Burner Coupling
- Burner Motor
- Cad Cell Eye
- Delayed Solenoid
- End Cone (Std-No Special Order)
- Ignition Wiring
- Nozzle Line
- Burner Fan
- Buss Bar Transformer Leads
- Delayed Oil Valve
- Electrodes
- Nozzle
FUEL SUPPLY PARTS
- Flare Fittings at Fuel Pump
- Fuel Filter Complete
- Flare Fitting at Fuel Filter
- Fuel Pump
- Fuel Pump Strainer
- Fuel Filter Cartridge
- Fuel Pump Bleeder
- In-line Oil Valve
WARM AIR FURNACE SYSTEM PARTS
- Air Diffuser (Limit 1)
- Blower Motor – 1/3 hp
- Blower Motor – 1/4 hp
- Blower Wheel
- Fan Limit Switch
- Blower Pulley
- Fan Relay
- Std 1″Disp. Air Filter (Limit 2)
- *Electronic Control Boards NOT Covered
- *ECM, Constant Torque Belt-Drive Motors NOT Covered
SERVICES
- Bleeding of Radiators (Where Accessible),(1 Hour Maximum in Plan Year)
- Purging of heating system (1 Hour Maximum in Plan Year)
- Adjust Boiler Pressure
ANNUAL TUNE-UP
The Annual Tune-Up is included in all of our Plans and will be performed once during the service agreement term during normal working hours as scheduled by our office. The Annual Tune-Up includes:
- Test and adjust oil burner for maximum efficiency.
- Visual inspect of combustion chamber, as accessible.
- Clean & check electrodes ad nozzle assembly.
- Replace Air Filter (Std. 1″ Disposable Series Only), if necessary.
- Replace Oil Filter Cartridge, if necessary.
- Replace Burner Nozzle, if necessary.
- Oil Motors on burner, fans circulators.
- Check safety & operating controls.
- Check oil tank & lines for visible leaks.
- Vacuum furnace, flue-pipe if necessary.
- Vacuum chimney base if necessary & accessible.
HOT WATER BOILER SYSTEM PARTS
- Air Vent/Hi Vent (Limit 1)
- Blow Down Valves
- Circulator Impeller
- Circulator Switch
- Combustion Chamber (If Accessible)
- Extrol Tank
- Flow Valve
- Mixing Valve (Limit 1)
- Taco Zone Valves (Limit 1)
- Taco Powerhead (Limit 1)
- Zone Valve Motor (Limit 1)
- Boiler Valves (Limit 2)
- Circulator Motor (Limit 1)
- Circulator Wicking
- Complete Taco Circulator (Limit 1)
- Feed Valve
- Low Water Cut off
- Pressuretrol
- Relief Valve (Limit 1)
- Transformer – Low Voltage
- Zone Valve Relay (Limit 1)
- Bearing Assembly (Limit 1)
- Circulator Coupling
- Circulator Motor Mounts
- Combination Control
- Expansion Tank
- Fitrol Tank
- Mixing Valve Element (Limit 1)
- Purge Valve at Boiler (Replace Only)
- Solenoid Valve
- Triple-Acting Aquastat
- Zone Valve Stem (Limit 1)
- Pressure Temperature Gauge